TXT
묘사:
Self-rectifying Vibrator
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
7
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Tube plug
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.935 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.500 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+0.0/+65.0 degrees celsius
MRC:
Indicates the type of coil used.APAG
Coil Type:
Not isolated
MRC:
The designation that identifies the schematic diagram of the contact configuration.APFR
Contact Arrangement:
Two circuit, double throw
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
Between 4.0 dc volts and 8.0 dc volts
MRC:
Indicates the type of unit.APQB
Unit Type:
Electromechanical
MRC:
Indicates the type of base furnished with the item.AWET
Base Type:
Standard base
MRC:
An indication of whether or not a hermetically sealed feature is provided.AXNN
Hermetically Sealed Feature:
Provided
MRC:
The amount of input current for which the item is rated.AZSL
Input Current Rating:
8.0 amperes
MRC:
An indication of whether the drive voltage is the same as,or different from,the input voltage.BGRB
Drive Voltage Relationship To Input Voltage:
Equal
MRC:
An indication of whether the output voltage is the same as,or different from,the input voltage.BGRH
Output/input Voltage Relationship:
Not rated
MRC:
Indicates the type of reed provided.BGRJ
Reed Type:
Dual
MRC:
An indication of whether the item is designed to actuate /make/ a contact before or after the preceding contact deactuates /breaks/.BGRK
Contact Operation Sequence:
Breaks before makes
MRC:
The value,or range of values,for which the contact is rated.BGRL
Contact Voltage Rating:
4.0 volts dry and 8.0 volts with retaining chain
MRC:
The amount of current for which the contact is rated.BGRM
Contact Current Rating:
8.0 amperes
MRC:
That portion of each driving cycle during which electrical continuity exists between the center contact and one stationary contact,expressed in degrees.BGRP
Dwell Time Rating In Deg:
Between 35.0 and 43.0
MRC:
An indication of whether or not a feature for plug in mounting is provided.BGRS
Plug In Mounting Feature:
Provided
MRC:
The size designation of the mounting base as it is commercially known and/or identified.BGRT
Base Mounting Size Designation:
7 pin standard tube
MRC:
An indication of the arrangement of the terminal pattern.BGRW
Terminal Pattern Arrangement:
0.750 in. Diameter terminal pin circle
MRC:
The style designation indicating the configuration that most nearly corresponds to the wiring of the base connection.BGRX
Base Connection Wiring Style:
7 pin standard tube