TXT
묘사:
Steam-hot Water Hea Water Heater
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
36.000 inches
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the outside circumference.ABKV
Outside Diameter:
18.375 inches
MRC:
The installed position for which the item is designed.ADSM
Mounting Position:
Horizontal
MRC:
The rated heating capacity of the item per hour.AMHR
Heating Capacity Per Hour:
600.000 gallons
MRC:
Indicates the capacity of the tank.AMKA
Tank Capacity:
30.0 gallons
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the water inlet connection.AMLL
Water Inlet Connection Thread Size And Series/type Designator:
1-1/4-11-1/2 npt
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the water outlet connection.AMLM
Water Outlet Connection Thread Size And Series/type Designator:
1-1/4-11-1/2 npt
MRC:
The number of water inlet connections.AMLQ
Water Inlet Connection Quantity:
1
MRC:
The number of water outlet connections.AMLR
Water Outlet Connection Quantity:
1
MRC:
The maximum pressure at which the heating coil is designed to operate.AMRE
Heating Coil Maximum Operating Pressure:
35.0 pounds per square inch
MRC:
An indication of the surface area of a heating coil.AMRF
Heating Coil Surface Area:
11.000 square feet
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Bronze, naval and nickel copper alloy
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy and nickel alloy
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
As differentiated by tank capacity, material, outside diameter, length, heating coil operating pressure, heating coil surface area, heating capacity per hour, water inlet connection quantity, water inlet connection thread size and series/type designator, water outlet connection quantity, water outlet connection thread size and series/type deisgnator