부품 정보
S202 directional control valve, 2-way, 2-position poppet
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Stem
MRC:
The position of the moving member/s/ controlling flow through the valve with the solenoid in the de-energized position.ADSK
Flow Control Device Normal Operation Position:
Closed
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
248.0 degrees fahrenheit single response
MRC:
The minimum temperature at which the item is designed to operate.AEQJ
Minimum Operating Temp:
-4.0 degrees fahrenheit
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Power unit, hydraulic
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Solenoid
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
3000.0 pounds per square inch single response
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
110.0 ac
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Complete valve s202 (normally closed); nitrile seals; 2 screw manual overide; 1/4" bsp port sizes; din43650 coil termination; compatible with most general purpose hydraulic fluids
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum alloy body lining
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Err-090