MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Single pole type					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						2.000 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
					 
					
						Body Width:
					
					
						1.250 inches 					
				 
							
					
						MRC:
						The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
					 
					
						Case Material:
					
					
						Plastic					
				 
							
					
						MRC:
						The center to center distance between terminals parallel to the length of the item.AEBP
					 
					
						Center To Center Distance Between Terminals Parallel To Length:
					
					
						0.906 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
					 
					
						Unthreaded Mounting Hole Diameter:
					
					
						0.250 inches 					
				 
							
					
						MRC:
						The distance between centerlines of mounting facilities parallel to the length of the item.AEBY
					 
					
						Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
					
					
						1.574 inches 					
				 
							
					
					
						Mounting Surface To Terminal End Distance:
					
					
						1.266 inches 					
				 
							
					
						MRC:
						The number of poles included in the item.AKPX
					 
					
						Pole Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						2 unthreaded hole					
				 
							
					
						MRC:
						Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.BBRG
					 
					
						Storage Type:
					
					
						General purpose warehouse					
				 
							
					
						MRC:
						The maximum current load that each pole is rated to carry continuously.CPLM
					 
					
						Maximum Continuous Load Current Rating Per Pole:
					
					
						10.0 amperes ac single location and 10.0 amperes dc single location					
				 
							
					
						MRC:
						Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.CPRF
					 
					
						Operating Voltage Type And Rating Per Pole In Volts:
					
					
						110.0 ac single location and 30.0 dc single location					
				 
							
					
						MRC:
						Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.CPRG
					 
					
						Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
					
					
						900.0 ac single location and 900.0 dc single location					
				 
							
					
						MRC:
						Indicates the type of electrical condition that will cause the device to trip.CPRH
					 
					
						Circuit Protection Type:
					
					
						Overcurrent single location					
				 
							
					
						MRC:
						The means by which the trip mechanism is released.CPRJ
					 
					
						Trip Release Method:
					
					
						Thermal single location					
				 
							
					
						MRC:
						Denotes the type of trip release action.CPRL
					 
					
						Trip Release Characteristic:
					
					
						Time delay single location					
				 
							
					
						MRC:
						The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.CPRN
					 
					
						Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
					
					
						130.0 single location					
				 
							
					
						MRC:
						The means provided to reposition the mechanism so that the device is ready to function.CPRQ
					 
					
						Reset Method:
					
					
						Automatic					
				 
							
					
						MRC:
						The basic internal electrical configuration of the trip mechanism.CPSM
					 
					
						Internal Trip Release Configuration:
					
					
						Series trip single location					
				 
							
					
						MRC:
						The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.CQWN
					 
					
						Trip Delay Time In Seconds Per Rated Continuous Current:
					
					
						6.000  at 200 pct single location and 50.000  at 200 pct single location					
				 
							
					
						MRC:
						Indicates the type of protection for which the inclosure is designed.CQXF
					 
					
						Inclosure Protection Type For Which Designed:
					
					
						Fungus resistant					
				 
							
					
						MRC:
						The temperature of the medium surrounding the trip release at which it can be operated continuously.CRCF
					 
					
						Trip Release Ambient Tempurature Rating:
					
					
						25.0 degrees celsius  single location					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the alternating current.FREQ
					 
					
						Frequency In Hertz:
					
					
						400.0 single location					
				 
							
					
						MRC:
						The measured weight of an item unencumbered by packaging or packing material.PKWT
					 
					
						Unpackaged Unit Weight:
					
					
						1.500 ounces					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						2 screw