TXT
묘사:
Power Supply Assembly
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
49.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
8.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
35.000 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Dripproof
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Ship control station
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
Indicates the type of power unit included with the item.AMKG
Power Unit Type:
Transformer power step-up single operating power rqmt
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Panel
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Three single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
115.0 ac pounds per hour wet single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
15.0 dc volts 1st power output and 16.5 dc volts 1st power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
-28.0 dc volts 3rd power output and 30.0 dc volts 3rd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
5.0 dc volts 2nd power output and 6.0 dc volts 2nd power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
60.0 hertz single operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.0/+65.0 degrees celsius
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment 2nd power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment 3rd power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment 1st power output
MRC:
The number of power units provided.BGQF
Power Unit Quantity:
1
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Dc voltmeter and fuse and indicator light
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
0.0 dc amperes 1st power output and 4.0 dc amperes 1st power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
0.0 dc amperes 2nd power output and 80.0 dc amperes 2nd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
0.0 dc amperes 3rd power output and 2.0 dc amperes 3rd power output
MRC:
An indication of whether current or voltage or both are controlled,stabilized,or limited to obtain the required output power characteristics.CWGW
Power Supply Output Current/voltage Characteristics:
Constant voltage 1st power output
MRC:
An indication of whether current or voltage or both are controlled,stabilized,or limited to obtain the required output power characteristics.CWGW
Power Supply Output Current/voltage Characteristics:
Constant voltage 2nd power output
MRC:
An indication of whether current or voltage or both are controlled,stabilized,or limited to obtain the required output power characteristics.CWGW
Power Supply Output Current/voltage Characteristics:
Constant voltage 3rd power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
1 1st power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
1 2nd power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
1 3rd power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Terminal strip 1st power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Terminal strip 2nd power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Terminal strip 3rd power output
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Terminal strip single operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
1 single operating power rqmt
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Convection
MRC:
The number of power supplies controlled by a programmable power supply.CXNJ
Power Supplies Programmed Per System:
3