MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						0.500 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						0.570 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						0.300 inches 					
				 
							
					
						MRC:
						The measurement of the distance that the actuator protrudes from the body.AFGK
					 
					
						Actuator Length:
					
					
						0.150 inches 					
				 
							
					
					
						Actuator Height:
					
					
						0.200 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the actuator,in distinction from thickness.AFUT
					 
					
						Actuator Width:
					
					
						0.150 inches 					
				 
							
					
						MRC:
						The relationship between the actuator position and the actuator action /maintained or momentary/.AFUX
					 
					
						Actuator Position-action Relationship:
					
					
						Left position maintained and  right position maintained					
				 
							
					
						MRC:
						The hue or tint of the actuator.AFVA
					 
					
						Actuator Color:
					
					
						Black single actuator					
				 
							
					
						MRC:
						The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
					 
					
						Maximum Voltage Rating In Volts:
					
					
						120.0 ac					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Integral					
				 
							
					
						MRC:
						The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
					 
					
						Nonpile-up Contact Arrangement:
					
					
						2 pole,  double throw,  both positions maintained single switch unit					
				 
							
					
						MRC:
						The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
					 
					
						Contact Load Current Rating At Maximum Rated Voltage:
					
					
						0.500 amperes resistive ac					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						6 printed circuit