TXT
묘사:
Power Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.201 inches single group
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase single component
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Assy. Low voltage power supply 440v ac inp 320v dc otp 12.25kw
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole single group
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
10 tab, solder lug