TXT
묘사:
Refrigerating Condensing Unit
MRC:
The gage pressure of gas delivered by the last stage of compression. referred to as condensing pressure for refrigeration compressors.AAXM
Discharge Pressure:
126.6 pounds per square inch gage
MRC:
The cooling medium used to maintain the required operating temperature of the compressor.AAXR
Compressor Cooling Medium:
Air
MRC:
The refrigeration capacity of the item as rated by industry,expressed in tons per hour.AAYE
Refrigeration Flow Rate In Tons Per Hour:
8.900
MRC:
The pressure of the gas after it has passed through the evaporator and prior to its compression within the item.AAYF
Suction Pressure:
41.7 pounds per square inch
MRC:
The speed of the compressor required to produce its rated capacity,expressed in revolutions per minute.AAYS
Compressor Speed At Rated Capacity In Rpm:
1750.0
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Refrigerant 12
MRC:
The speed of the drive shaft required to produce the rated capacity of an item,expressed in revolutions per minute.AEQC
Operating Speed At Rated Capacity In Rpm:
1750.0
MRC:
The rated horsepower of the prime mover.AHZX
Prime Mover Horsepower Rating:
10.0
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Direct
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
The temperature of the medium surrounding an item at which it can be operated.ANDX
Ambient Temp:
122.0 degrees fahrenheit
MRC:
The type of water with which the item is designed to be used.AWCD
Water For Which Designed:
Salt
MRC:
Indicates the type of compressing unit provided.AWLG
Compressing Unit Type:
Reciprocating
MRC:
Indicates the design type of the compressing unit.AWLH
Compressing Unit Design Type:
Open
MRC:
The number of cylinders provided in the compressing unit.AWLJ
Compressing Unit Cylinder Quantity:
3
MRC:
The length of a straight line which passes through the center of the circular cross-sectional plane of the cylinder bore,and terminates at the circumference.AWLK
Compressing Unit Cylinder Bore Diameter:
2.500 inches
MRC:
The cooling medium used to maintain the required operating temperature of the condenser.AWLL
Condenser Cooling Medium:
Water
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the condenser.AWLM
Condenserlength:
6.000 feet
MRC:
The length of a straight line which passes through the center of the condenser shell,and terminates at the outside circumference.AWLN
Condenser Shell Outside Diameter:
6.625 inches
MRC:
Indicates the type of condenser.AWLP
Condenser Type:
Fin or tube
MRC:
The number of electric motors provided.AWLX
Electric Motor Quantity:
1
MRC:
The component for which the item is designed.AWLY
Component For Which Designed:
Compressor
MRC:
A measurement of the longest dimension of the stroke of a compressing unit,in distinction from width.AWWM
Compressing Unit Stroke Length:
2.000 inches
MRC:
The amount of heat transfer area of the condenser.AWXH
Condenser Heat Transfer Area:
62.900 square feet
MRC:
A measurement of the capacity of a separate liquid receiver.AWXJ
Separate Liquid Receiver Capacity:
1.500 cubic feet
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0