Fluid Cooler Core Assembly
MRC:
A measurement of the longest dimension of the core,in distinction from width.AKMJ
Core Length:
13.563 inches
MRC:
A measurement taken at right angles to the length of the core,in distinction from thickness.AKMK
Core Width:
Between 3.859 inches and 3.891 inches
MRC:
The length of a straight line which passes through the center of the tubing,and terminates at the outside circumference.AQRX
Tubing Outside Diameter:
0.250 inches both inlet and outlet tube ends
MRC:
The number of tubes included on the item.ARNF
Tube Quantity:
28
MRC:
A measurement from the bottom to the top of the core,in distinction from depth.ARPN
Core Height:
Between 2.797 inches and 2.829 inches
MRC:
The means by which the tube/s/ is attached.AWMZ
Tube Attachment Method:
Expanded both ends
MRC:
A measurement of the surface of the item that effects the transfer of heat.CTRC
Effective Heat Transfer Surface Area:
2.0 square feet
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper tubes
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Astm b111-51 assn standard single material response tubes