MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flow.ADQS
Flow Style:
Four-way three port bottom outlet 360 degree plug turn
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
250.0 degrees fahrenheit single response
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Automatic
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
3000.0 pounds per square inch single response
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy body
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Water-oil-gas single response