부품 정보
						Arbitray generator 33250a
					 
				 
						
			
				
					TXT
				
				
					묘사:
				
				
					Electronic Te Function Generator				
			 
			
							
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						348.0 millimeters 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						89.0 millimeters 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						213.0 millimeters 					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						+0.0/+55.0 degrees celsius					
				 
							
					
						MRC:
						A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
					 
					
						Average Life Measurement:
					
					
						Not rated					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						Adavanced digital test syste (adts) 					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
					 
					
						Basic Shape Style:
					
					
						Rectangular or square					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Encased					
				 
							
					
						MRC:
						The means by which the item is operated or controlled.ALBM
					 
					
						Operating Control Method:
					
					
						Automatic or manual					
				 
							
					
						MRC:
						The installation for which the item is designed.AMQY
					 
					
						Installation Design:
					
					
						Rack					
				 
							
					
						MRC:
						Indicates the type of control.AQZF
					 
					
						Control Type:
					
					
						Local or remote					
				 
							
					
						MRC:
						Indicates the type of circuit construction provided in the item.BHSX
					 
					
						Circuit Construction Type:
					
					
						Solid state					
				 
							
					
						MRC:
						Indicates the type of signal data per channel.BHTZ
					 
					
						Signal Data Type Per Channel:
					
					
						1st output channel synchro err-100					
				 
							
					
						MRC:
						Indicates the type of signal data per channel.BHTZ
					 
					
						Signal Data Type Per Channel:
					
					
						2nd output channel analog voltage err-100					
				 
							
					
						MRC:
						Indicates the type of signal data per channel.BHTZ
					 
					
						Signal Data Type Per Channel:
					
					
						2nd output channel pulse err-100					
				 
							
					
						MRC:
						Indicates the type of signal data per channel.BHTZ
					 
					
						Signal Data Type Per Channel:
					
					
						2nd output channel pulse,  amplitude err-100					
				 
							
					
						MRC:
						Indicates the type of signal data per channel.BHTZ
					 
					
						Signal Data Type Per Channel:
					
					
						2nd output channel sweep err-100					
				 
							
					
						MRC:
						The physical configuration of the output wave.BJBJ
					 
					
						Output Wave Shape:
					
					
						Pulse,  variable width and sine and square					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the operating alternating current.BJBQ
					 
					
						Operating Ac Frequency In Hertz:
					
					
						50.0  1st voltage and 60.0  1st voltage					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the operating alternating current.BJBQ
					 
					
						Operating Ac Frequency In Hertz:
					
					
						50.0  2nd voltage and 400.0  2nd voltage					
				 
							
					
						MRC:
						The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
					 
					
						External Ac Operating Voltage In Volts:
					
					
						100.0  1st voltage and 240.0  1st voltage					
				 
							
					
						MRC:
						The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
					 
					
						External Ac Operating Voltage In Volts:
					
					
						100.0  2nd voltage and 127.0  2nd voltage					
				 
							
					
						MRC:
						Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
					 
					
						Special Features:
					
					
						80mhz sine and squarewave outputs 50mhz pulse waveforms with variable rise and fall times,  12bit 200msa/s 64k point deep arbitrary waveform,  color graphical display,  waveform types are:  sine;  square;  pulse;  ramp;  noise;  sinx over x;  exponential rise and fall;  cardiac;  dc volts,  warmup time 1 hour,  weight 4.6 kg,  dimensions 213mm wide;  89mm high;  348mm deep,  this is a modified agilent 33250a with option 1cm (rackmount kit) and option aba (english manual