TXT
묘사:
Radio Frequency Transmiss Switch
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.375 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.688 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.375 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.0 gigahertz 1st frequency insertion loss reference and 0.5 gigahertz 1st frequency insertion loss reference
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.0 gigahertz 1st frequency voltage standing wave ratio and 0.5 gigahertz 1st frequency voltage standing wave ratio
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.0 gigahertz 3rd frequency rf power handling and 0.5 gigahertz 3rd frequency rf power handling
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.5 gigahertz 2nd frequency insertion loss reference and 3.0 gigahertz 2nd frequency insertion loss reference
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.5 gigahertz 2nd frequency rf power handling and 3.0 gigahertz 2nd frequency rf power handling
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.5 gigahertz 2nd frequency voltage standing wave ratio and 1.0 gigahertz 2nd frequency voltage standing wave ratio
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
1.0 gigahertz 3rd frequency voltage standing wave ratio and 6.0 gigahertz 3rd frequency voltage standing wave ratio
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
3.0 gigahertz 1st frequency rf power handling and 6.0 gigahertz 1st frequency rf power handling
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
3.0 gigahertz 3rd frequency insertion loss reference and 6.0 gigahertz 3rd frequency insertion loss reference
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.0 gigahertz and 0.5 gigahertz 1st frequency insertion loss reference
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.0 gigahertz and 0.5 gigahertz 1st frequency voltage standing wave ratio
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.0 gigahertz and 0.5 gigahertz 3rd frequency rf power handling
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.5 gigahertz and 1.0 gigahertz 2nd frequency voltage standing wave ratio
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.5 gigahertz and 3.0 gigahertz 2nd frequency insertion loss reference
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.5 gigahertz and 3.0 gigahertz 2nd frequency rf power handling
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
1.0 gigahertz and 6.0 gigahertz 3rd frequency voltage standing wave ratio
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
3.0 gigahertz and 6.0 gigahertz 3rd frequency insertion loss reference
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
3.0 gigahertz and 6.0 gigahertz 1st frequency rf power handling
MRC:
Indicates the type of switch included in the item.AEEA
Switch Type:
Nontransfer
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+100.0 degrees celsius
MRC:
A letter or group of letters used to designate the particular coaxial connector series.AHUC
Coaxial Connector Series Designation:
Bnc
MRC:
The value/s/,or range of values,of potential for which the item is rated,expressed in volts.AKPJ
Actuator Voltage In Volts:
26.0
MRC:
An indication of whether the lobe of the rotating cam is designed to actuate /make/ a switch before or after the preceding switch deactuates /breaks/.AKPN
Switch Operation Sequence:
Makes before breaks
MRC:
The time required for switching between any two adjacent positions.AKPP
Switching Time:
25.0 milliseconds
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
2
MRC:
The maximum radio frequency voltage that the insulating materials of the item will withstand without resulting in disruptive discharge or deterioration.AKQA
Rf Maximum Voltage Rating:
1.0 kilovolts peak
MRC:
The number of coupling positions provided.AKRC
Coupling Position Quantity:
3
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 turret and 3 receptacle, coaxial