부품 번호 357-029

Power Supply

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards
부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
357-029
비무장화:
No
수명:
측정 단위:
NIIN:
000898126
NSN
국가 주식 번호:
6130-00-089-8126 6130000898126
TXT
묘사:
Power Supply
INC
INC
아이템 이름 코드:
00740
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
13.250 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
6.000 inches
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
10000.0 feet
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Bracket
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single single operating power rqmt
MRC:
The ratio of permissible frequency deviation from the controlled constant value,expressed in percent.ANRQ
Frequency Regulation Percent:
1.0 1st power output
MRC:
The ratio of permissible frequency deviation from the controlled constant value,expressed in percent.ANRQ
Frequency Regulation Percent:
1.0 2nd power output
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
115.0 ac volts single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
0.95 dc kilovolts 2nd power output and 1.05 dc kilovolts 2nd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
19.5 dc kilovolts 1st power output and 20.5 dc kilovolts 1st power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
398.0 hertz single operating power rqmt and 402.0 hertz single operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.1 to 150.0 degrees fahrenheit
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Fixed voltage 1st power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Fixed voltage 2nd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
50.0 dc microamperes 1st power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
20.0 dc microamperes 2nd power output
MRC:
The maximum alternating current voltage variation which may be present on the direct current output voltage level.CWGZ
Ripple Voltage At Full Load:
1.0 volts peak 2nd power output
MRC:
The maximum alternating current voltage variation which may be present on the direct current output voltage level.CWGZ
Ripple Voltage At Full Load:
20.0 volts peak 1st power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
1 1st power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
1 2nd power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Connector, receptacle 2nd power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Connector, receptacle 1st power output
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Connector, receptacle single operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
1 single operating power rqmt
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Ambient air
MRC:
The time required for a power supply(ies) to reach the full operating potential for which it is rated,expressed in minutes.CWKM
Warm Up Time In Minutes:
2