TXT
묘사:
Dial Indicating Pressure Gage
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.750 inches
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Steel
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the case.ADTY
Case Surface Treatment:
Dichromate
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Aircraft, delta dart f-106; support equipment h3, b52, and f4 aircraft
MRC:
The increment of measure represented by the marking/s/ on the item.ANBJ
Graduation Unit:
5.0 pounds per square inch
MRC:
Indicates the type of actuation provided.APCM
Actuation Type:
Diaphragm
MRC:
An indication of whether or not the item is adjustable.APCS
Adjustability:
Nonadjustable
MRC:
An indication of the scale range.APSK
Scale Range:
+0.0/+50.0 pounds pressure per square inch
MRC:
The nomenclature by which the scale is identified.AQFZ
Scale Name:
Oil pressure
MRC:
The hue or tint of the pointer.ASSS
Pointer Color:
White
MRC:
Indicates the type of pointer provided.ASST
Pointer Type:
Indicating
MRC:
Indicates the type of scale.ATEQ
Scale Type:
Single
MRC:
The smallest value between the markings on a scale.AWAG
Scale Smallest Increment:
1.0 pounds per square inch
MRC:
The element,compound,or mixture of which an actuating element is fabricated,excluding any surface treatment.BGKY
Actuating Element Material:
Phosphor bronze
MRC:
The hue or tint of the inscription(s) and/or that portion of the scale which surrounds the inscription on the scale.BGKZ
Scale Inscription/background Color:
White figures, black background
MRC:
Indicates the connection location.BGRY
Connection Location:
Back, center
MRC:
The element,compound,or mixture of which the protective crystal is fabricated,excluding any surface treatment.BHMF
Protective Crystal Material:
Glass
MRC:
Designates the size of the connection provided.BHMG
Connection Size:
0.125 in. Npt dia
MRC:
An indication of whether or not a connector type vent is provided.BHMK
Connector Type Vent:
Not provided