TXT
묘사:
Vertical Tube Manometer
MRC:
The maximum pressure at which an item is designed to operate.AAJJ
Maximum Operating Pressure:
20.0 pounds per square inch
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Base
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
1 bottle indicating fluid d-2930; 1 mercury thermometer; 1 magnifier
MRC:
An indication of whether or not an adjuster to return the item to zero is provided.ANTC
Zero Adjuster:
Provided
MRC:
An indication of the scale range.APSK
Scale Range:
+0.000/+20.000 inches
MRC:
Indicates the type of receptacle provided.ATMG
Receptacle Type:
Well
MRC:
The smallest value between the markings on a scale.AWAG
Scale Smallest Increment:
0.100 inches
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded
MRC:
Indicates the type of facility(ies) provided to connect the item.BDGB
Connection Facility Type:
Internal
MRC:
Indicates the connection location.BGRY
Connection Location:
Top left side and top right side
MRC:
An indication of whether or not a feature for eliminating parallax is provided.BHMM
Parallax Eliminating Feature:
Provided
MRC:
The indicating liquid for which the item is designed.BHMN
Indicating Liquid For Which Designed:
Water indicating liquid d2930
MRC:
An indication of whether or not indicating liquid is provided.BHMP
Indicating Liquid:
Provided
MRC:
An indication of whether or not a control valve is provided.BHMQ
Control Valve:
Provided
MRC:
An indication of whether or not an equalizing valve is provided.BHMR
Equalizing Valve:
Provided
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.THDS
Thread Size And Series/type Designator:
0.250-18 npt
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
As differentiated by scale range