TXT
묘사:
Alternating Current Generator
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise single end
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Horizontal mounting position
MRC:
The amount of electrical energy that can be dissipated.CNXS
Power Rating:
1.560 kilowatts output
MRC:
The amount of current for which an item is rated,expressed in amperes.CWGL
Current Rating In Amps:
65.000 single output
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
24.0 line to neutral single output
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 binding post