부품 번호 3357-3

Electromagnetic Relay

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards
부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
3357-3
비무장화:
No
수명:
측정 단위:
NIIN:
005524021

부품 정보
Insulated coil requires a grounded push switch for operation

NSN
국가 주식 번호:
5945-00-552-4021 5945005524021
TXT
묘사:
Electromagnetic Relay
INC
INC
아이템 이름 코드:
32512
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.400 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.500 inches
MRC:
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
Mounting Slot Width:
0.375 inches single mounting facility
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Hermetic
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
1
MRC:
The number of coils included on the item.APCN
Coil Quantity:
1
MRC:
The measured opposition to the flow of direct current offered by the item winding.APNA
Winding Dc Resistance Rating:
19.0 ohms single winding
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Continuous
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 slotted hole single mounting facility
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
In-line single mounting facility
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.CRNG
Nonpile-up Main Contact Arrangement:
1 pole, single throw, normally closed, momentary action
MRC:
The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.CRPQ
Operating Current Rating And Type:
3.25 amperes dc single winding
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the altitude of an isosceles triangle.CSQJ
Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle:
2.125 inches single mounting facility
MRC:
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.CSXF
Operating Voltage Rating And Type At Specificationified Temp:
6.0 volts dc 25 degrees celsius single winding
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
35.0 amperes dc resistive load
MRC:
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.CWAB
Main Contact Maximum Voltage Rating In Volts:
6.0 dc
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
3 pin all functions

{lang[cimilar]} Electromagnetic Relaies

« Relays and Solenoids {lang[catalog]}
지금 비교»
맑다 | 숨기다