묘사:
Centrifugal Pump Unit
MRC:
The number of prime movers incorporated in the unit.AAXH
Prime Mover Quantity:
1
MRC:
The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
Prime Mover Cooling Medium:
Air
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Hydrocarbon fuels and oils
MRC:
The vertical distance from the level of supply to the center of the pump.AHYY
Suction Lift:
25.000 feet
MRC:
The speed of the item required to produce its rated capacity.AHYZ
Operating Speed At Rated Capacity:
1200.0 revolutions per minute
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Self-priming
MRC:
The rated power of the prime mover.CSYL
Prime Mover Power Rating:
0.500 horsepower
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0 and 230.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0