부품 정보
Gray marking on edge.
TXT
묘사:
Electrical Special Purpose Cable
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Flat
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-20.0 degrees celsius and 105.0 degrees celsius
MRC:
A measurement from the bottom to the top of a cross section,in distinction from depth.ADVN
Cross-sectional Height:
0.035 inches
MRC:
A measurement of the cross section taken at right angles to the length,in distinction from thickness.ADWH
Cross-sectional Width:
1.000 inches
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
20
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
19 all conductors
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Stranded all conductors
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
28 awg all conductors
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
40 all conductors
MRC:
The arrangement and number of arrangements of the conductors.CXDQ
Conductor Arrangement And Quantity:
20 molded together w/no outer covering
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
300.0 root mean square (rms) operating voltage all conductors
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black 1st position primary insulation all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy core conductor all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyvinyl chloride 1st position primary insulation all conductors
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
Surface all conductors. Silver
MRC:
Identification of the precious material contained in the item.PRMT
Precious Material:
Silver
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Silver core conductor all conductors