부품 정보
Electrostatic discharge sensitive
TXT
묘사:
Electronic Control Amplifier
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.600 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.600 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-40.0/+95.0 degrees celsius
MRC:
The numeric value of the life expectancy of the item.AFHH
Average Life Rating:
20000.0
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Hours
MRC:
The numeric value indicating the average life expectancy for which the item is rated,expressed in hours.AFSV
Average Life Rating In Hours:
20000.0
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
An/alr-56 aewr
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
80000.0 feet
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Automatic
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Mechanical
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
700.0 megahertz operating channel and 1300.0 megahertz operating channel
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
50.000 ohms operating channel
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
Operating channel digital err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
Operating channel radio frequency err-100
MRC:
Indicates the type of connection and its location on the item.BJBP
Connection Type And Location:
Receptacle, coaxial bottom and connector, plug top and receptacle, coaxial top
MRC:
Indicates the type and number of contact(s) included in the connection.BJBW
Connection Contact Type And Quantity:
1 connector, plug external and 5 receptacle, coaxial external
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
15.0 3rd voltage err-100
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
5.0 1st voltage err-100
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
-15.0 2nd voltage err-100
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
As differentiated by source control drawing