부품 정보
Cable assembly w1 checks for presence of 26vac and secondary 19vac outputs; w2 checks baroset function for accuracy and backlash, w3 checks synchro inputs and outputs, w4 provides the capability to test select the values of r 10 and r36 in unit under test, provides a synchro input with a readout indicating altitude in feet equivalent to syncro input and provides capabilities to observe synchro outputs of uut on the auxiliary oscilloscope
TXT
묘사:
Electronic Altimeter Test Set
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
21.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
400.0 hertz
MRC:
The principal parts that are included in an assembled unit.AEAS
Major Components:
Console assembly; four interconnecting cables; holding fixture for the electronic board assemblies; extender board
MRC:
A linear measurement from the surface to a specified inner point on an item,in distinction from height.AEJZ
Depth:
20.000 inches
MRC:
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.AFJK
Cubic Measure:
4200.000 cubic inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Aau-19a/a
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Single item w/housing
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Fault isolation tests for electronic altimeter aau-19a/a
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Checks proper operation of the electrical components of the aau-19a/a altimeter
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
10.000 inches
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
T.O.33da72-6-1