TXT
묘사:
Electrical Contact
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
0.518 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.078 inches
MRC:
The length of a straight line which passes through the center of the cable entrance,and terminates at the circumference.AFQJ
Cable Entrance Diameter:
0.040 inches
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
5.0
MRC:
The means of attaching the item.AXGY
Mounting Method:
Any acceptable
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper body
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper contact
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
External surface gold
MRC:
An indication of the precious material contained in the item,and the amount per a measurement scale.PMWT
Precious Material And Weight:
0.005 gold grains, troy
MRC:
Identification of the precious material contained in the item.PRMT
Precious Material:
Gold
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Gold body
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Gold contact
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Socket crimp contact
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
10001-58a5a285 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
1 solder well end opposite contact