TXT
묘사:
Power Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
25.0 kilohertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.630 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
Body Outside Diameter:
1.320 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
130.0 degrees celsius
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary single component and 3 secondary single component
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
14.0 milliamperes ac single component 3rd secondary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
1.0 amperes ac single component 2nd secondary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
75.0 milliamperes ac single component single primary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
750.0 milliamperes ac single component 1st secondary
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
1.4 volts-amperes single component 3rd secondary
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
2.7 volts-amperes single component single primary
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
26.0 volts-amperes single component 2nd secondary
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
9.0 volts-amperes single component 1st secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
100.00 ac volts single component 3rd secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
12.00 ac volts single component 1st secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
3.00 ac volts single component single primary and 33.00 ac volts single component single primary and 36.00 ac volts single component single primary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
7.00 ac volts single component 2nd secondary and 19.00 ac volts single component 2nd secondary and 26.00 ac volts single component 2nd secondary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
15 pin