MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
2
MRC:
Indicates the type of intake connection included on the item.AAYU
Intake Connection Type:
Round flange
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
2
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Oval flange
MRC:
Indicates the type of connection between the prime mover and the shaft.AAYX
Drive Connection Type:
Rigid coupled
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Hydrocarbon fuels and oils
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
112.0 gallons per minute
MRC:
The pressure of the media delivered by the item at maximum rated discharge capacity.AHYW
Discharge Pressure:
25.0 pounds per square inch gage
MRC:
The vertical distance from the level of supply to the center of the pump.AHYY
Suction Lift:
10.000 feet
MRC:
The speed of the item required to produce its rated capacity.AHYZ
Operating Speed At Rated Capacity:
1318.0 revolutions per minute
MRC:
The design of a rotary pump as determined by the mechanical principle used to achieve movement of the fluid.AHZR
Rotary Pump Design:
Gear
MRC:
The means by which the item is operated.AHZT
Operation Method:
Powered
MRC:
Indicates the type of drive shaft by the physical configuration,condition,and the like of the shaft end.AJAB
Drive Shaft Type:
Splined, involute external