MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Portable case
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
13.125 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
6.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
7.625 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 400.0 hertz
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Metal
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the case.ADTY
Case Surface Treatment:
Enamel, gray
MRC:
The range of complete cyclic changes,per unit of time,for which an item is rated.AFGQ
Frequency Range Rating:
+10.000/+500.000 megahertz
MRC:
The range of complete cyclic changes,per unit of time,for which an item is rated.AFGQ
Frequency Range Rating:
+10.000 to 500.000 megahertz
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The total opposition (resistive and reactive) presented by the item to an alternating current load.AMNE
Output Impedance Rating:
50.0 ohms
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
Between 105.0 volts and 125.0 volts and 210.0 volts and 250.0 volts
MRC:
The number of specified ranges of frequencies or wavelengths operating between two stated limits.ANLC
Frequency Band Quantity:
6
MRC:
The degree of conformity of a measurement to a standard or true value for which the calibration is rated.BDHW
Calibration Accuracy Rating:
Porm 2.000 percentaccuracy on all bands
MRC:
An indication of whether or not a crystal controlled feature is provided.BHFY
Crystal Controlled Feature:
Not provided
MRC:
An indication of the maximum signal output transmitted by the item.BHGB
Maximum Signal Output:
200 mw 10 to 130 mhz, 150 mw 130 to 260 mhz, 25 mw 260 to 500 mhz into matched load
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Countermeasures set