부품 정보
Oxygen regulator field tester
TXT
묘사:
Demand Oxygen Regulat Test Stand
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Portable
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
F-15 acft
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
16.31 x 8.41 x 9.18; 24 lbs
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Used to verify proper operation of the oxygen regulator which c/o of 9 tests: flow, air check valve operation, suction flow, air ratio shutoff, pressure breathing, outlet leakage, demand vave leakage, blinker flow and mask pressure
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
T.O. 33d2-10-55-4; serd no. 0755
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Power 28vdc, 4 amps, source/battery