부품 번호 31TA1593B

Flow Rate Indicating Meter

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards
부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
31ta1593b
비무장화:
No
수명:
측정 단위:
NIIN:
008018239
NSN
국가 주식 번호:
6680-00-801-8239 6680008018239
TXT
묘사:
Flow Rate Indicating Meter
INC
INC
아이템 이름 코드:
38346
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
36.000 inches
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Hose nipple
MRC:
An indication of whether or not an integral safety device is included.AHZU
Integral Relief Valve:
Not included
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Adapter for 3/4 in. Id hose fitting, 4
MRC:
Indicates the design type of the item.APGF
Design Type:
Case
MRC:
Indicates the type of unit.APQB
Unit Type:
Portable
MRC:
The number of scales on the item.APSJ
Scale Quantity:
1
MRC:
The structural characteristic of the item.ARQS
Construction:
Inclosed w/sight window
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Hose nipple
MRC:
Indicates the type of scale.ATEQ
Scale Type:
Millimeter reference reading
MRC:
The number of floats provided.AWAE
Float Quantity:
3
MRC:
The element,compound,or mixture of which the tube is fabricated,excluding any surface treatment.AWGJ
Tube Material:
Glass
MRC:
An indication of whether or not a carrying handle is included.AXQG
Carrying Handle:
Included
MRC:
The minimum and maximum markings on a dial scale.BHBY
Dial Scale Marking Range:
+1.0/+1800.0
MRC:
Designates the size of the outlet connection included on the item.BHCM
Outlet Connection Size:
3/4 in.
MRC:
An indication of whether or not a base(s) is included.BHJT
Base:
Included
MRC:
Indicates the type of float used.BHSQ
Float Type:
Free
MRC:
The element,compound,or mixture of which the float is fabricated,excluding any surface treatment.BJDM
Float Material:
Steel, stainless
MRC:
An indication of whether or not an integral heat source is included.BNHN
Integral Heat Source:
Not included
MRC:
The maximum working pressure at which an item is designed to operate.BPHD
Maximum Working Pressure:
240.0 pounds per square inch
MRC:
Designates the size of the inlet connection included on the item.CPZD
Inlet Connection Size:
3/4 in.
MRC:
The number of metering tubes provided.CPZF
Metering Tube Quantity:
3
MRC:
The maximum amount of air for which the item is rated,expressed in cubic feet per minute.CPZH
Maximum Air Capacity In Cubic Feet Per Minute:
200.0
MRC:
The smallest increment of graduation on the dial scale.CPZJ
Dial Scale Smallest Increment:
1 mm
MRC:
An indication of whether or not a dial scale reference pointer is included.CPZK
Dial Scale Reference Pointer:
Not included
MRC:
The number of floats in each tube.CPZL
Float Quantity Per Tube:
1
MRC:
An indication of whether or not a spinning float is included.CPZM
Spinning Float:
Included
MRC:
An indication of whether or not an integral pulsation dampener is included.CPZN
Integral Pulsation Dampener:
Not included
MRC:
The inlet connection position for which the item is designed.CPZP
Inlet Connection Position For Which Designed:
Horizontal
MRC:
Indicates the type of inlet connection device provided.CPZQ
Inlet Connection Device Type:
Stationary
MRC:
The outlet connection position for which the item is designed.CPZR
Outlet Connection Position For Which Designed:
Horizontal
MRC:
Indicates the type of outlet connection device provided.CPZS
Outlet Connection Device Type:
Stationary
MRC:
An indication of whether or not an alarm signal is included.CPZT
Alarm Signal:
Not included

{lang[cimilar]} Flow Rate Indicating Meters

« Liquid and Gas Flow, Liquid Level and Mechanical Motion Measuring Instruments {lang[catalog]}
지금 비교»
맑다 | 숨기다