TXT
묘사:
Wire Wound Fixed Resistor
MRC:
A measure of the opposition to the flow of electrical current.AAPP
Electrical Resistance:
1.020 ohms
MRC:
The limits of permissible variation in the electrical resistance value of an item from its rated value,expressed in percent.AAPQ
Resistance Tolerance In Percent:
-10.000/+10.000
MRC:
The number of fixed terminals at points between the end terminals that provide connection to intermediate values of the total value.AAPR
Fixed Tap Quantity:
1
MRC:
The ambient temperature of the medium surrounding an item at which it can be operated continuously at full rated power,expressed in degrees celsius.AAQF
Ambient Tempurature In Deg Celsius At Full Rated Power:
50.0
MRC:
The ambient temperature at which the power dissipation of an item is operated to zero percent of the full rated power,expressed in degrees celsius.AAQG
Ambient Tempurature In Deg Celsius At Zero Percent Rated Power:
425.0
MRC:
The means provided to coat,cover,or protect the item.AAQZ
Inclosure Method:
Uninclosed
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Tab, solder lug
MRC:
The inductive or noninductive condition resulting from the method used in placing /winding/ wire on a form in the construction of electrical components.AARE
Reactance Characteristic:
Inductive
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
1.875 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
2.125 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
11.812 inches
MRC:
The distance between centerlines of mounting facilities parallel to the length of the item.AEBY
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
13.000 inches
MRC:
The maximum amount of electrical energy that can be expended by an item,expressed in watts.AEFB
Power Dissipation Rating In Watts:
820.000 free air
MRC:
A measurement taken at right angles to the length of the terminal,in distinction from thickness.AFWW
Terminal Width:
0.500 inches
MRC:
Designates the size of the relative or proportionate dimension of the mounting hole.BYML
Mounting Hole Size:
0.531 inches
MRC:
A measure of the nominal opposition to the flow of electric current through the section.CQFD
Section Resistance:
0.510 ohms
MRC:
Indicates the type of terminal/s/ on the fixed tap/s/ that is provided for electrical connection.CQFK
Fixed Tap Terminal Type:
Tab, solder lug
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Radial terminal each end
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
Ew form