TXT
묘사:
Rota Electro-mechanical Actuator
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
50000.0 feet
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Counterclockwise
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Direct
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
1.0
MRC:
The rated torque of the output drive.AWQM
Output Drive Torque Rating:
50.0 foot-pounds
MRC:
An indication of whether or not a limit switch control is included.AWQN
Limit Switch Control:
Not included
MRC:
An indication of whether or not a manual override is included.AWQR
Manual Override:
Not included
MRC:
The maximum operating on time and the minimum off time for a complete cycle of an item.AYEK
Intermittent Operation Duty Cycle:
3.0 minutes on and 17.0 minutes off
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
26.0