TXT
묘사:
Non-wire Wound Variable Resistor
MRC:
The number of individual elements.AAPN
Section Quantity:
1
MRC:
The length of a straight line which passes through the center of that portion used to guide the item and terminates at the circumference.AAVL
Pilot Diameter:
Between 0.7495 inches and 0.7500 inches
MRC:
The length of the pilot,which is the unthreaded portion beyond the thread used to guide the item.AAVM
Pilot Length:
Between 0.0570 inches and 0.0670 inches
Undercut Diameter:
0.750 inches
Undercut Width:
Between 0.0570 inches and 0.0607 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
Between 0.870 inches and 0.880 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.060 inches
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
Between 0.253 inches and 0.263 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 0.440 inches and 0.470 inches
Mounting Lip Diameter:
Between 0.8700 inches and 0.8800 inches
Mounting Lip Depth:
Between 0.0570 inches and 0.0670 inches
MRC:
Indicates the type of facility or arrangement provided for moving the variable contact(s).AEFD
Actuator Type:
Single shaft
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Rear end
MRC:
The means of attaching the item.AXGY
Mounting Method:
Clamp ring
MRC:
A measure of the opposition to the flow of direct or alternating current per section.CQCC
Electrical Resistance Per Section:
16000.000 ohms single section
MRC:
The maximum amount of electrical energy that can be expended per section,expressed in watts.CRGD
Power Dissipation Rating Per Section In Watts:
0.2 free air single section
MRC:
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
Resistance Tolerance Per Section In Percent:
-1.9/+1.9 single section
MRC:
The ambient temperature,expressed in degrees celsius,of the medium surrounding each section at which it can be operated continuously at full rated power.CSDH
Ambient Tempurature In Deg Celsius Per Section At Full Rated Power:
98.8 single section
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
3 wire lead