TXT
묘사:
Fire Control System Test Set
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
17.500 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
20.500 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
220.0 volts
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
230.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 420.0 hertz
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Aluminum carrying case
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Single item w/carrying case
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Calibration of range circuits and displays; calibration of range-rate v; test of target velocity accommodation /opening and closing/; test for range-gate stealing susceptibility; test for jamming susceptibility; test for chaff and decoy susceptibility; test for range v transients; test for system ability to accommodate maneuvering target; test for rate-memory time constant; test for acceleration tolerance while in rate-memory
MRC:
The testing functions such as range,sensitivity,output,and the like,for which the item is designed.AQXZ
Operating Test Capability:
Range calibration target range 0 to 10000 yards and 0 to 100000 yards; rate calibration target rate 0 to 5000 knots; acceleration calibration /opening or closing/ target acceleration 0 to 50 g; pre-target range from target 0 to 6 pct full scale; internal pulse rate freq generator range 25 to 5000 pulses per sec; output pulse characteristics polarity pos or neg amplitude /50 ohm load/ 0-50 v rise 0.10 usec nom decay 0.15 usec nom width 0.6 usec nom output impedance 50 ohms; external trigger porm 30 v nom external trigger; target modulation external sensitivi type 5 v dc 100 pct modulation internal frequency 25 to 5000 cps
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
8.000 inches