Jacket: unichrome no. 219p4 primer with black unichrome super 5300 jacket 0.01 in. Thick; peak power 0-35 kw; ambient temperature rang 0 to plus 65 degrees c
TXT
묘사:
Waveguide Assembly
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Internal, rectangular external, rectangular
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Radar set an/spg-51c
MRC:
The style designation indicating the configuration that most nearly corresponds to the construction of the tubing wall.AHRV
Tubing Wall Construction Style:
Seamless all tubing segment
MRC:
The number of flanges provided with the item.AHSF
Flange Quantity:
2
MRC:
The length of a straight line which passes through the center of a flange,and terminates at the outside circumference.AHTC
Flange Outside Diameter:
3.250 inches first flange
MRC:
The length of a straight line which passes through the center of a flange,and terminates at the outside circumference.AHTC
Flange Outside Diameter:
3.750 inches second flange
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.690 inches second flange
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.800 inches first flange
MRC:
The length of a straight line which passes through the center of a flange connecting hole,and terminates at the circumference.AHTN
Flange Connecting Hole Diameter:
0.127 inches second flange all connection facilities and 0.130 inches second flange all connection facilities
MRC:
The length of a straight line which passes through the center of a flange connecting hole,and terminates at the circumference.AHTN
Flange Connecting Hole Diameter:
0.219 inches first flange all connection facilities and 0.222 inches first flange all connection facilities
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.15
MRC:
The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
Insertion Loss In Decibels:
0.07
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
10.0 pounds per square inch gage
Waveguide Outside Width:
Between 1.713 inches and 1.723 inches
Waveguide Inside Width:
Between 1.585 inches and 1.595 inches
Waveguide Inside Height:
Between 0.790 inches and 0.800 inches
Waveguide Outside Height:
Between 0.918 inches and 0.928 inches
MRC:
The type and number of facilities by which the flange is connected.CSQT
Flange Connecting Facility And Quantity:
2 unthreaded hole second flange all connection facilities
MRC:
The type and number of facilities by which the flange is connected.CSQT
Flange Connecting Facility And Quantity:
6 unthreaded hole first flange all connection facilities
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Flexible first tubing segment
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Rigid fourth tubing segment
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Rigid second tubing segment
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Rigid third tubing segment
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Rigid fifth tubing segment
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy all tubing segment and flange
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Paint all flange outside surfaces
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Offset bend type
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Antennas, waveguides, and related equipment