부품 정보
Thermocouple junction compensation module, type k

NSN
국가 주식 번호:
6685-01-253-7705 6685012537705
TXT
묘사:
Thermocouple Junctio Compensator
INC
INC
아이템 이름 코드:
77777
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.800 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.700 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.000 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
P/n 501580-001; f107-wr101/400 turbofan engine
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Self powered item by 3 replaceable standard aaa type cells; battery life 500 hours continuous; on/off power switch; operates over a range of 10 to 50 degrees c; compensation accuracy +/- 1/4 degrees c at 25 degrees c, +/- 1/2 degrees c from 15 to 35 degrees c ambient, and +/- 3/4 degrees c from 10 to 50 degrees c ambient; output impedance less than 100 ohms
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Used in testing, calibrating, or troubleshooting the icats thermocouple temperature measurement system, or individual type k thermocouple probes; when used with the thermocouple calibrator produces outputs, or reads inputs, referenced to 32 degrees f, 0 degrees c, and autimatically compensates for ambient temperature changes
MRC:
A recording of the physical,functional,and performance characteristics for an item of supply.TEXT
General Description:
To use the compensator it is plugged directly into the top terminal posts of the t/c calibrator; the thermocouple probe or the output cable is then plugged into the top of the compensator; using the t/c junction compensation module eliminates the need for an ice bath