MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
3.000 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
1.500 inches
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
1
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
12
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Steel case
MRC:
The plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the item and its location.ANNR
Surface Treatment And Location:
Painted case
MRC:
The total oppositon (resistive and reactive) which the item offers to the input flow of alternating current.ANSL
Input Impedance Rating:
500.000 ohms
MRC:
The total opposition (resistive and reactive) which the item offers to the output flow of alternating current.ANSR
Output Impedance Rating:
500.000 ohms
MRC:
The differences between limiting frequencies of a frequency band.APQL
Frequency Bandwidth:
900.0 hertz
MRC:
A measurement between specified points on a body in distinction from height.ARBR
Body Depth:
0.560 inches
MRC:
The facility for mounting the item.AZGM
Mounting Facility:
Terminal
MRC:
The means by which the signal is delayed.BZWM
Signal Delay Method:
Lumped constant
MRC:
The means used to vary the delay time of the item.CCDN
Delay Time Variation Method:
Tapped
MRC:
The time delay of each section of an item.CCDQ
Section Delay Time:
6.670 microseconds single section
MRC:
The number of segments into which a section is divided.CCDR
Segment Quantity Per Section:
10 single section
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
0.667 microseconds single section all segments
MRC:
Indicates the type and number of terminals for providing electrical connection.CCFF
Terminal Type And Quantity:
12 pin
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Radar sets, nonairborne, except fire control and guided missile