TXT
				
				
					묘사:
				
				
					Fluid Pressure Regulating Valve				
			 
			
										
					
						MRC:
						The basic material of which the body is fabricated.AAFZ
					 
					
						Body Material:
					
					
						Any acceptable					
				 
							
					
					
						First End Flange Outside Diameter:
					
					
						7.688 inches 					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Straight thru					
				 
							
					
						MRC:
						The element, compound,or mixture of which the stem is fabricated,excluding any surface treatment.ABEP
					 
					
						Stem Material:
					
					
						Any acceptable					
				 
							
					
						MRC:
						The type of service with which the item is designed to be used.ACKL
					 
					
						Media For Which Designed:
					
					
						Water,  fresh and water,  salt					
				 
							
					
						MRC:
						A narrative description of the type of end connection.ACKM
					 
					
						First End Connection Type:
					
					
						Plain face flange					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
					 
					
						First End Style Designator:
					
					
						Plain					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the shape of the end flange.ACKT
					 
					
						First End Flange Shape Style:
					
					
						Round w/ bolt holes					
				 
							
					
						MRC:
						A measurement of the smallest dimension of the first end flange, in distinction from length or width.ACKU
					 
					
						First End Flange Thickness:
					
					
						0.500 inches 					
				 
							
					
						MRC:
						The number of bolt holes provided on the item.ACKZ
					 
					
						First End Bolt Hole Quantity:
					
					
						8					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of a bolt hole,and terminates at the circumference.ACLA
					 
					
						First End Bolt Hole Diameter:
					
					
						0.563 inches 					
				 
							
					
					
						First End Bolt Circle Diameter:
					
					
						6.563 inches 					
				 
							
					
						MRC:
						Indicates whether or not the second end is identical to the first end.ACLR
					 
					
						Second End Relationship With First End:
					
					
						Identical					
				 
							
					
						MRC:
						The element,compound,or mixture of which the seating surfaces are fabricated.ACSH
					 
					
						Seat Material:
					
					
						Any acceptable					
				 
							
					
					
						Face To Face Distance:
					
					
						13.500 inches 					
				 
							
					
						MRC:
						The element,compound,or mixture of which the packing is fabricated.ADQT
					 
					
						Packing Material:
					
					
						Any acceptable					
				 
							
					
						MRC:
						The part that controls the flow through the item.ADQU
					 
					
						Flow Control Device:
					
					
						Diaphragm					
				 
							
					
						MRC:
						The element,compound,or mixture of which the flow control device is fabricated.ADQV
					 
					
						Flow Control Device Material:
					
					
						Any acceptable					
				 
							
					
						MRC:
						The element,compound,or mixture of which the flow control device is fabricated.ADQV
					 
					
						Flow Control Device Material:
					
					
						Any acceptableany acceptable					
				 
							
					
						MRC:
						The number of end connections included in the item.ADQZ
					 
					
						End Connection Quantity:
					
					
						2					
				 
							
					
						MRC:
						Indicates the type of renewable seating ring in the item.ADZH
					 
					
						Renewable Seat Ring Type:
					
					
						Threaded					
				 
							
					
						MRC:
						The minimum to maximum limits of outlet pressure of the item.AEVA
					 
					
						Outlet Pressure Range:
					
					
						+25.0/+60.0 pounds per square inch					
				 
							
					
						MRC:
						The minimum to maximum limits of outlet pressure of the item.AEVA
					 
					
						Outlet Pressure Range:
					
					
						+25.0 to 60.0 pounds per square inch					
				 
							
					
						MRC:
						Indicates the basic design type used for regulating the item.AEVN
					 
					
						Regulation Type:
					
					
						Automatic double stage					
				 
							
					
						MRC:
						The seat design of the valve stem.AEVQ
					 
					
						Valve Stem Design:
					
					
						Single seat					
				 
							
					
						MRC:
						The seat design of the valve stem.AEVQ
					 
					
						Valve Stem Design:
					
					
						Single seatsingle seat					
				 
							
					
						MRC:
						The means of providing resistance to the media passing through a valve,whereby the valve is actuated to regulate the flow.AEVR
					 
					
						Valve Loading Method:
					
					
						Spring					
				 
							
					
						MRC:
						The maximum pressure of the media on the inlet side at which an item is designed to operate.AEVZ
					 
					
						Maximum Inlet Pressure Rating:
					
					
						150.0 pounds per square inch					
				 
							
					
						MRC:
						The rated variance of the outlet pressure from the set pressure.AEWB
					 
					
						Outlet Pressure Accuracy Rating:
					
					
						Not rated					
				 
							
					
						MRC:
						An indication of whether or not a filter is included.AEWF
					 
					
						Filter:
					
					
						Not included					
				 
							
					
						MRC:
						A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.AZKQ
					 
					
						Tempurature Rating:
					
					
						165.0 degrees fahrenheit 					
				 
							
					
						MRC:
						Test conditions and ratings,or environmental and performance requirements that are different,more critical,or more specific than those specified in a governing test data document.SPCL
					 
					
						Special Test Features:
					
					
						High-impact shock tests are required as directed in paragraphs 3.6 and 4.4.2.3 of mil-v-2042 in pac test above					
				 
							
					
						MRC:
						The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
					 
					
						Test Data Document:
					
					
						81349-milv2042 specification (includes engineering type bulletins,  brochures, etc.,  that reflect specification type data in specification format;  excludes commercial catalogs,  industry directories,  and similar trade publications,  reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical",  "average",  "",  etc.).					
				 
							
					
						MRC:
						The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
					 
					
						Specification Or Standard:
					
					
						2 type