부품 번호 3075AS141

Line Electro-mechanical Actuator

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards

이 제품의 과거 가격은 5692.83 and 7444.47 USD. 수량, 가용성, 상태, 리드 타임 및 품목 중단 가능성에 따라 최신 견적을 제공할 때까지 가격을 보장할 수 없습니다.

부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
3075as141
비무장화:
Yes - DEMIL/MLI
수명:
N/A
측정 단위:
1 EA
NIIN:
014374948

부품 정보
Used on mobile aircraft salvage crash cranes on board us navy aircraft carrier ships

NSN
국가 주식 번호:
3010-01-437-4948 3010014374948
TXT
묘사:
Line Electro-mechanical Actuator
INC
INC
아이템 이름 코드:
10957
INC
COM
컴플라이언스:
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Insulated wire lead
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-25.0 degrees fahrenheit and 125.0 degrees fahrenheit
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
2.950 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
20.550 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Moisture proof and watertight
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Variable
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
0.2
MRC:
A measurement of the longest dimension of the stroke,in distinction from width.AMWL
Stroke Length:
3.900 inches
MRC:
An indication of whether or not a limit switch control is included.AWQN
Limit Switch Control:
Included
MRC:
The means used to reset the thermal protector.AWQP
Thermal Protector Reset Method:
Automatic
MRC:
An indication of whether or not a manual override is included.AWQR
Manual Override:
Not included
MRC:
The rate of linear travel per unit of time.AWTE
Rated Stroke Velocity:
1.900 inches per second
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
440.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0

{lang[cimilar]} Line Electro-mechanical Actuators

« Torque Converters and Speed Changers {lang[catalog]}
지금 비교»
맑다 | 숨기다