MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
5
MRC:
Items furnished as accessories which are not specified elsewhere.AFJH
Furnished Items:
Case, radiac set; radiacmeter; radiacmeter test sample; power supply; strap, carrying
MRC:
The name of the government agency or commercial organization that controls the manufacture of the accessory item.AKVY
Accessory Controlling Agency:
Sheller-globe corp
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
Cy-2073/pdr-43 type no.
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
Im-125/pdr-43 type no.
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
Mx-2608/pdr-43 type no.
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
Pp-2123/u type no.
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
St-134/u type no.
MRC:
The name assigned to the item by the joint electronics type designation system.AKWA
Joint Electronics Type Designation System Item Name:
Radiac set
MRC:
The type number assigned to the item by the joint electronics type designation system.AKWB
Joint Electronics Type Designation System Item Type Number:
An/pdr-43
MRC:
Indicates the designed use of the item.ALCD
Usage Design:
Detect beta and gamma rays; measure gama rays
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Included
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Meter
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Gamma rays detects
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Beta rays detects
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Gamma rays measures
MRC:
Indicates the type of detecting element included.AMRX
Detecting Element Type:
Geiger tube
MRC:
The minimum and maximum amount of radiation detected per hour.APPJ
Radiation Range Per Hour:
+0.0/+500.0 roentgens
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
3.0 dc
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
3.0