Radio Frequency Transmiss Switch
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.562 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.000 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
2.0 megahertz single frequency operating and 30.0 megahertz single frequency operating2.0 megahertz single frequency crosstalk reference and 30.0 megahertz single frequency crosstalk reference
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
2.0 megahertz and 30.0 megahertz single frequency operating2.0 megahertz and 30.0 megahertz single frequency crosstalk reference
MRC:
Indicates the type of switch included in the item.AEEA
Switch Type:
Transfer
MRC:
The longest distance between mounting centers parallel to the horizontal plane.AFDS
Longest Horizontal Distance Between Mounting Centers:
0.875 inches single mounting facility pattern
MRC:
The longest distance between mounting centers parallel to the vertical plane.AFDV
Longest Vertical Distance Between Mounting Centers:
0.875 inches single mounting facility pattern
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.05 single
MRC:
The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
Insertion Loss In Decibels:
1.20 single
MRC:
A letter or group of letters used to designate the particular coaxial connector series.AHUC
Coaxial Connector Series Designation:
Bnc
MRC:
The amount of radio frequency power handling capability that can be dissipated safely by an item.AKNF
Rf Power Handling Capability:
100.0 watts average single
MRC:
The minimum amount of isolation the item offers against interference from adjacent channel operation,expressed in decibels.AKNV
Minimum Crosstalk Rating In Decibels:
35.0 single
MRC:
The means provided for switching the actuator from one position to another.AKPC
Actuator Operating Method:
Relay
MRC:
The value/s/,or range of values,of potential for which the item is rated,expressed in volts.AKPJ
Actuator Voltage In Volts:
32.0
MRC:
An indication of whether the lobe of the rotating cam is designed to actuate /make/ a switch before or after the preceding switch deactuates /breaks/.AKPN
Switch Operation Sequence:
Breaks before makes
MRC:
The operation of the switch mechanism when the switch return actuator power is removed.AKPQ
Switch Return Mechanism Type:
Fail-safe
MRC:
The number of coupling positions provided.AKRC
Coupling Position Quantity:
3
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 threaded hole
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.112 inches mounting facility hole
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Four position rectangular single mounting facility pattern
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc mounting facility hole
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 receptacle, coaxial