TXT
묘사:
Line Electro-mechanical Actuator
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Connector
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
12.880 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
2.190 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
3.620 inches
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
35000.0 feet
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
2.5
MRC:
A measurement of the longest dimension of the stroke,in distinction from width.AMWL
Stroke Length:
5.000 inches
MRC:
An indication of whether or not a limit switch control is included.AWQN
Limit Switch Control:
Included
MRC:
An indication of whether or not a manual override is included.AWQR
Manual Override:
Not included
MRC:
The tension stress applied to the item under load conditions.AWTA
Tension Load Rating:
1000.0 pounds static err-100
MRC:
The tension stress applied to the item under load conditions.AWTA
Tension Load Rating:
540.0 pounds operating err-100
MRC:
The tension stress applied to the item under load conditions.AWTA
Tension Load Rating:
1000.0 pounds static
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
27.0
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Antenna, transmitterset, telemetric data, airborne