MRC:
						The primary application for which the item is designed.AAFS
					 
					
						Application Design:
					
					
						Transmission line					
				 
							
					
						MRC:
						The basic material of which the body is fabricated.AAFZ
					 
					
						Body Material:
					
					
						Aluminum					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Rectangular,  terminal/terminals on opposite surfaces					
				 
							
					
						MRC:
						Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a body surface.ABEM
					 
					
						Body Surface Treatment:
					
					
						Anodized					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						7.040 inches 					
				 
							
					
						MRC:
						The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Length:
					
					
						6.240 inches 					
				 
							
					
						MRC:
						The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Width:
					
					
						0.680 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						1.300 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						1.000 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
					 
					
						Mounting Slot Width:
					
					
						0.180 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the mounting slot,in distinction from width.ABVG
					 
					
						Mounting Slot Length:
					
					
						0.320 inches 					
				 
							
					
						MRC:
						The number of holes/slots or studs provided for attaching the item to a surface.ADAE
					 
					
						Mounting Hole/stud Quantity:
					
					
						4					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						+0.0/+75.0 degrees celsius					
				 
							
					
						MRC:
						The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
					 
					
						Voltage Standing Wave Ratio:
					
					
						1.35					
				 
							
					
						MRC:
						The total opposition (resistive and reactive) which the item offers to the admittance of an entering flow of alternating current,expressed in ohms.AHTY
					 
					
						Input Impedance Rating In Ohms:
					
					
						50.0					
				 
							
					
						MRC:
						The total opposition /resistive and reactive/ which the output of the item provides to match,for maximum transfer of energy,the input impedance of another item,expressed in ohms.AHTZ
					 
					
						Output Impedance Rating In Ohms:
					
					
						50.0					
				 
							
					
						MRC:
						A letter or group of letters used to designate the particular coaxial connector series.AHUC
					 
					
						Coaxial Connector Series Designation:
					
					
						N					
				 
							
					
						MRC:
						The amount of electrical energy that can be dissipated.AJDB
					 
					
						Power Rating:
					
					
						20.0 watts average and 2.0 kilowatts peak					
				 
							
					
						MRC:
						The decrease in the strength of the radio frequency signals,expressed in decibels.AJDK
					 
					
						Rf Signal Attenuation In Decibels:
					
					
						17.7					
				 
							
					
						MRC:
						The minimum and maximum values of the frequency range in which the voltage standing wave ratio is specified.AKNK
					 
					
						Voltage Standing Wave Ratio Frequency Range:
					
					
						+0.0/+12.4 gigahertz					
				 
							
					
						MRC:
						The frequency at which the attenuation accuracy was measured.ASYE
					 
					
						Attenuation Accuracy Reference Frequency:
					
					
						12.4 gigahertz					
				 
							
					
						MRC:
						The limits of permissible variation in the attenuation accuracy from the nominal value at a specified frequency rating or range,expressed in decibels.ASYN
					 
					
						Attenuation Accuracy In Decibels:
					
					
						-0.02/+0.02					
				 
							
					
						MRC:
						Indicates the type of connection per function.ASZN
					 
					
						Connection Type Per Function:
					
					
						Female input and  female output					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Bracket					
				 
							
					
						MRC:
						Indicates the type and number of terminal(s) for providing electrical connection.BBHS
					 
					
						Terminal Type And Quantity:
					
					
						2 connector					
				 
							
					
						MRC:
						The minimum and maximum cyclic changes,per unit of time,for which an item is rated.BNGR
					 
					
						Frequency Range:
					
					
						Between 0.000 hertz and 12.400 gigahertz