TXT
묘사:
Meter Movement Relay
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
5
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Wire loop
MRC:
The standard of valuation as represented by the inscription.ABWC
Scale Unit Of Measure Inscription:
Volts
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
11
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Zinc
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Salt spray resistant and shock resistant and vibration resistant
MRC:
The hue or tint of the light emitted from that portion of the item which surrounds the inscription on the item.AETT
Inscription Background Color:
White
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Three no. 4-40 thd mtg studs space 120 degrees apart
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
50.0 volts
MRC:
The minimum and maximum numeric values representing the measurement coverage of a scale.ANSZ
Scale Measurement Range:
+3.0/+6.0
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the main contacts including the number of poles or forms.APDZ
Main Contact Arrangement:
1 pole, double throw, both positions maintained
MRC:
Indicates the type of current used by the main contact/s/.APEB
Main Contact Current Type:
Dc
MRC:
The current rating of the main contact/s/.APEC
Main Contact Current Rating:
Between 41.0 milliamperes and 74.0 milliamperes
MRC:
Indicates the type of current used in the meter movement.APGN
Meter Movement Current Type:
Ac
MRC:
The amount of voltage required to operate the meter movement,expressed in volts.APGP
Meter Movement Voltage In Volts:
Between 3.000 and 6.300
MRC:
The cycles per second /hertz/ of current of the meter movement.APML
Meter Movement Frequency Rating:
400.0 hertz
MRC:
The hue or tint of the dial scale marking(s).APMM
Dial Scale Marking Color:
Black
MRC:
An indication of whether or not the luminous scale marking/s/ are activated by ultraviolet.APMN
Err Default:
Err default
MRC:
An indication of whether or not the luminous scale marking/s/ are activated by ultraviolet.APMN
Dial Luminous Scale Marking Activation Type:
Not ultraviolet
MRC:
Indicates the type of mount utilized to support the meter.APMR
Meter Mounting Type:
Flush
MRC:
An indication of whether or not the reset facilities are provided.APNR
Reset Facility Feature:
Provided
MRC:
Indicates the type of lock in device provided.APNS
Lock In Device Type:
Locking coil
MRC:
The length of a straight line which passes through the center of the mounting flange,and terminates at the circumference.APTE
Mounting Flange Diameter:
2.800 inches
MRC:
The length of a straight line which passes through the center of the meter body and terminates at the circumference.APTF
Meter Body Diameter:
2.155 inches
MRC:
A measurement between the mounting flange and the face of the item, in distinction from height.APTN
Meter Depth To Mounting Flange:
2.000 inches