TXT
묘사:
Radio Frequency Transmiss Switch
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
12.4 gigahertz 2nd frequency insertion loss reference and 18.0 gigahertz 2nd frequency insertion loss reference
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
8.0 gigahertz 1st frequency insertion loss reference and 12.4 gigahertz 1st frequency insertion loss reference
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
8.0 gigahertz 1st frequency voltage standing wave ratio and 12.4 gigahertz 1st frequency voltage standing wave ratio
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
8.0 gigahertz single frequency rf power handling and 18.0 gigahertz single frequency rf power handling
MRC:
Indicates the type of switch included in the item.AEEA
Switch Type:
Nontransfer
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-40.0/+85.0 degrees celsius
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
An/usm-464
MRC:
A letter or group of letters used to designate the particular coaxial connector series.AHUC
Coaxial Connector Series Designation:
Sma
MRC:
The design of the connector end.AHUD
Connector End Design:
Female
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
15000.0 feet
MRC:
The actuator current type and amount of electron flow at which the item is designed to operate,expressed in amperes.AKPE
Actuator Current Type And Rating In Amps:
0.125 dc
MRC:
The value/s/,or range of values,of potential for which the item is rated,expressed in volts.AKPJ
Actuator Voltage In Volts:
Between 24.0 and 30.0
MRC:
An indication of whether the lobe of the rotating cam is designed to actuate /make/ a switch before or after the preceding switch deactuates /breaks/.AKPN
Switch Operation Sequence:
Breaks before makes
MRC:
The time required for switching between any two adjacent positions.AKPP
Switching Time:
20.0 milliseconds
MRC:
The operation of the switch mechanism when the switch return actuator power is removed.AKPQ
Switch Return Mechanism Type:
Fail-safe
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
2
MRC:
The maximum radio frequency voltage that the insulating materials of the item will withstand without resulting in disruptive discharge or deterioration.AKQA
Rf Maximum Voltage Rating:
500.0 volts rms