Viton mechanical seal; relief valve setting 55 porm 5 psig; foot mounted
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
Indicates the type of intake connection included on the item.AAYU
Intake Connection Type:
Square flange
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Square flange
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
5.5 gallons per minute
MRC:
The pressure of the media delivered by the item at maximum rated discharge capacity.AHYW
Discharge Pressure:
50.0 pounds per square inch gage
MRC:
The speed of the item required to produce its rated capacity.AHYZ
Operating Speed At Rated Capacity:
900.0 revolutions per minute
MRC:
The direction in which the pump shaft turns during operation.AHZD
Pump Rotation Direction:
Clockwise
MRC:
The design of a rotary pump as determined by the mechanical principle used to achieve movement of the fluid.AHZR
Rotary Pump Design:
Gear
MRC:
The means by which the item is operated.AHZT
Operation Method:
Powered
MRC:
Indicates the type of drive shaft by the physical configuration,condition,and the like of the shaft end.AJAB
Drive Shaft Type:
Woodruff keyway
MRC:
The length of a straight line which passes through the center of the drive shaft end,and terminates at the circumference.AJAC
Drive Shaft End Diameter:
1.000 inches
MRC:
A measurement of the distance the drive shaft extends from the housing.AJAD
Drive Shaft Length:
2.250 inches
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
As differentiated by the source control dwg no.