부품 정보
4 v to 20 v overvoltage protector
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.000 inches
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 2nd operating power rqmt
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 1st operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
108.0 ac pounds per hour dry 2nd operating power rqmt and 132.0 ac pounds per hour with retaining chain 2nd operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
5.0 dc volts single power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz 1st operating power rqmt and 63.0 hertz 1st operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz 2nd operating power rqmt and 63.0 hertz 2nd operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.1/+55.0 degrees celsius
MRC:
The means used to change alternating current voltage to direct current voltage.BHQN
Rectification Method:
Single phase full wave center tap
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Filter
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
3.0 dc amperes single power output