부품 정보
Weapon system essential
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Poppet
MRC:
The position of the moving member/s/ controlling flow through the valve with the solenoid in the de-energized position.ADSK
Flow Control Device Normal Operation Position:
Closed
MRC:
The number of bolt holes provided on the item.AECS
Bolt Hole Quantity:
4 1st end
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Oliver perry class ffg
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
1.100
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Solenoid
MRC:
The physical configuration of the flange.ARKN
Flange Shape:
Round with holes all ends
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Flange all ends
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Vertical
MRC:
Designates the size of the valve.CCFG
Valve Size:
1.500 inches
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
57.0 pounds per square inch single response
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
120.0 ac
MRC:
The nominal length of a straight line which passes through the center of an item,and terminates at the outside circumference.CWCD
Outside Diameter:
5.000 inches all ends
MRC:
The face to face distance.CWCF
Face To Face Distance:
10.620 inches
MRC:
A nominal measurement of the smallest dimension of an item,in distinction from length or width.CWCK
Thickness:
0.628 inches all ends
MRC:
The nominal length of a straight line which passes through the center of the bolt hole,and terminates at the circumference.CWCQ
Bolt Hole Diameter:
0.625 inches all ends
MRC:
The nominal length of a straight line which passes through the center of the bolt circle,and terminates at the circumference.CWCT
Bolt Circle Diameter:
3.880 inches all ends
MRC:
The design of the flange face.CWDF
Flange Face Design:
Raised straight all ends
MRC:
A nominal measurement from the bottom to the top surface of a raised face,in distinction from depth.CWDH
Raised Face Height:
0.062 inches all ends
MRC:
The nominal length of a straight line which passes through the center of a raised face,and terminates at the circumference.CWDL
Raised Face Diameter:
2.560 inches 1st end
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel comp 316 body
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Stainless steel flow control device
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Stainless steel seat
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Fuel/oil, hydrocarbon single response
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Err-090