MRC:
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.AASA
Thread Length:
0.365 inches single mounting facility and 0.380 inches single mounting facility
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.975 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.380 inches
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
1
MRC:
The general configuration of the contacts of a switch that describes its basic switching structure.AJZE
Switch Contact Basic Design:
Pile-up
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded bushing w/panel seal single mounting facility
MRC:
The voltage for which the contacts are rated,expressed in volts.CQMK
Contact Voltage Rating In Volts:
10.0 highest dc voltage rating at sea level
MRC:
The voltage for which the contacts are rated,expressed in volts.CQMK
Contact Voltage Rating In Volts:
5.0 lowest dc voltage rating at sea level
MRC:
An indication of the switching action by the contacts of the item.CSHW
Contact Switching Action:
Breaks before makes single section front
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
0.0033 milliamperes resistive load highest dc voltage rating at sea level
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
1.0 milliamperes resistive load lowest dc voltage rating at sea level
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Circular wafer, bushing mount