TXT
묘사:
Power Distribution Panel
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
4.656 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
16.000 inches
MRC:
The rated power that an item can safely consume or provide,measured in watts.ABJL
Wattage Rating In Watts:
Any acceptable
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
13.625 inches
MRC:
The means of attaching the item.ADJH
Mounting Method:
Wall
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
4
MRC:
Items furnished as accessories which are not specified elsewhere.AFJH
Furnished Items:
Relay, switch
MRC:
The name of the government agency or commercial organization that controls the manufacture of the accessory item.AKVY
Accessory Controlling Agency:
Ward leonard electric co, arrow-hart and hegeman
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
150 part no. And 80634 type no.
MRC:
The element,compound,or mixture of which the panel is fabricated,excluding any surface treatment.ANJG
Panel Material:
Steel
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Dripproof
MRC:
The number of complete cyclic changes,per unit of time,for which the output frequency is rated.ANSQ
Output Frequency Rating:
60 hertz
MRC:
The number of panels provided.APCA
Panel Quantity:
1
MRC:
The number of electrical inputs accommodated.APNW
Electrical Input Quantity:
2
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
120.0 ac pounds per hour wet
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
120.0 ac volts
MRC:
An indication of whether or not an input neutral is provided.APNY
Input Neutral:
Not provided
MRC:
The number of electrical outputs provided.APNZ
Electrical Output Quantity:
1
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
120.0 ac volts
MRC:
The rated output power that an item can safely consume or provide,measured in watts.APPB
Output Wattage Rating In Watts:
Any acceptable
MRC:
An indication of whether or not an output neutral is provided.APPC
Output Neutral:
Not provided
MRC:
The cycles per second /hertz/ of input alternating current.APPY
Input Frequency In Hertz:
60.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Enameled