TXT
묘사:
Power Supply Assembly
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
7.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
19.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
18.500 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
An/frt-31, transmitting set, radio
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 1st alternate operating power rqmt
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 1st operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
105.0 ac pounds per hour dry 1st alternate operating power rqmt and 125.0 ac pounds per hour with retaining chain 1st alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
105.0 ac pounds per hour dry 1st operating power rqmt and 125.0 ac pounds per hour with retaining chain 1st operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
24.0 dc volts multiple power outputs w/identical ratings
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
50.0 hertz 1st operating power rqmt and 400.0 hertz 1st operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
50.0 hertz 1st alternate operating power rqmt and 400.0 hertz 1st alternate operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-20.0/+71.0 degrees celsius
MRC:
The number of power units provided.BGQF
Power Unit Quantity:
2
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
11.7 dc amperes multiple power outputs w/identical ratings
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
4 multiple power outputs w/identical ratings
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Terminal strip multiple power outputs w/identical ratings
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Terminal strip 1st alternate operating power rqmt
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Terminal strip 1st operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
2 1st operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
2 1st alternate operating power rqmt