부품 정보
Reversible switch action
TXT
묘사:
Liquid Level Switch
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
13.187 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
5.562 inches
MRC:
The identifying numeric code of the originator that controls or manufactures the electrical connector receptacle.AEEE
Connector Manufacturer Code:
04034
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Buoyancy
MRC:
Indicates the type of electrical connection included on the item.AGBD
Electrical Connection Type:
Connector receptacle
MRC:
The specification,standard,or manufacturer's number or symbol used to identify the connector.AGBG
Connector Identification:
3102-16s-8p
MRC:
The number of floats provided.AWAE
Float Quantity:
1
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
250.0 degrees fahrenheit
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Vertical
MRC:
The designation that identifies the schematic diagram of the contact arrangement.BJKD
Contact Arrangement:
Single pole single throw normally open
MRC:
An indication of whether or not a relay is included.BJKG
Relay:
Not included
MRC:
Indicates the type of liquid(s) for which the item is designed.BJKH
Liquid Type For Which Designed:
Water
MRC:
The distance of the effective travel of the float.BJKN
Float Effective Travel:
0.500 inches
MRC:
The mounting dimensions of the item.BJKP
Mounting Dimensions:
Mtd by six 9/16 in. Dia. Holes equally spaced on 4.438 in. Diameter bolt circle
MRC:
A measurement of the longest dimension from the mounting surface to the end of the item,which is designed to be inserted into the tank.BJKQ
Tank Insertion Length:
10.750 inches