TXT
묘사:
Waveguide Assembly
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Internal, rectangular external, rectangular
MRC:
The angular measurement by which one part/section of a rigid item deviates from a straight line projection of an adjacent part/section,expressed in degrees.ACJL
Bend Angle In Deg:
71.0 single bend e-plane
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Missile guidance and tracking set an/spg-55b
MRC:
The style designation indicating the configuration that most nearly corresponds to the construction of the tubing wall.AHRV
Tubing Wall Construction Style:
Seamless single tubing segment
MRC:
The number of flanges provided with the item.AHSF
Flange Quantity:
2
Flange Inside Width:
1.872 inches first flange
Flange Inside Height:
0.872 inches first flange
Flange Outside Width:
3.437 inches first flange
Flange Outside Height:
2.500 inches first flange
MRC:
The length of a straight line which passes through the center of a flange connecting hole,and terminates at the circumference.AHTN
Flange Connecting Hole Diameter:
0.203 inches first flange all connection facilities
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
20.0 pounds per square inch gage
Waveguide Outside Width:
Between 1.990 inches and 2.010 inches
Waveguide Inside Width:
Between 1.867 inches and 1.877 inches
Waveguide Inside Height:
Between 0.867 inches and 0.877 inches
Waveguide Outside Height:
Between 0.990 inches and 1.010 inches
Waveguide Longer Offset Distance:
5.155 inches
MRC:
The type and number of facilities by which the flange is connected.CSQT
Flange Connecting Facility And Quantity:
8 unthreaded hole first flange all connection facilities
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Contact type first flangecover type second flange
Waveguide Offset Distance:
2.742 inches
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Rigid single tubing segment
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Paint all tubing segment and flange outside surfaceschromate all tubing segment and flange all surfaces
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Bend type
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Antennas, waveguides, and related equipment